Soldering tester (UNI-TESTER)
Soldering tester for both robotic and manual soldering
In addition to the tip temperature, Uni-Tester can measure the tip leakage voltage and ground resistance simultaneously. (also available for hand soldering) Compatible with the latest international standards such as the new IEC-61191-1 (Ed3 / 2018) and IPC J-STD-001G.
- The tester that can measure tip temperature, the tip leakage voltage and ground resistance.
- Separate system (controller and sensor unit) considering installation onto a robot.
- The tester can deliver and share records to external devices with serial communication.
- The records can be utilized in various applications such as automatic tip temperature offset.
- The measuring range of ground resistance is 0-999kΩ, compatible with IEC-61191-1 (Ed3 / 2018).
- The measuring range of the tip leakage voltage corresponds to IEC-61191-1 (Ed3 / 2018), IPC J-STD-001G, JIS-C61191-1.
- ”PEAK HOLD ” function that holds the highest value and “AUTO ZERO ” function that resets leakage voltage and ground resistance.
Measurement range of UNI-TESTER for various standards
IPC | IEC | JIS | |
---|---|---|---|
Standard | IPC J-STD-001G Issued in 2017 |
IEC-C61191-1(Ed3/2018) Issued in 2018 |
JIS-C61191-1 (Planned to change after 2019) |
Tip leakage voltage | Not specified | 2mV (RMS) or less | 2mV (RMS) or less |
Transient voltage | 2V peak or less | 2V peak or less | 2V peak or less | Tip to ground resistance | 5Ω or less | 5Ω or less For overcurrent protection, 1MΩ or more |
5Ω or less |
Measurement range of UNI-TESTER. Supports three typical international and Japan standards.